Lantai timbul ventilasi baja · VF-1

Nomor Model: VF-1

Pesanan Minimum: 10 m²

Deskripsi Produk

The shell is similar to the anti-static steel access floor panel, but the inside of the shell is empty — no cement. The top and bottom steel plates are perforated, and some types of bottom are reinforced by ribs. The perforated panel is used in areas that need ventilation and is often installed together with the steel anti-static access floor. The perforated rate ranges from 17% to 50% according to the requirement of the application, and the covering can be HPL, PVC or ceramic tile. Steel perforated panels are also called air flow panels because of the many holes drilled through them; they are of accurate size and thickness and interchangeable with steel, wood core or calcium sulphate panels. A specially designed and well manufactured damper is available for the perforated panels.

Konstruksi & struktur

The ventilation panel shares the steel shell of the solid panel but the cavity stays empty — no cement filling. Top and bottom plates are punched with the same pattern, and an HPL or PVC facing is bonded on top. Used together with solid panels wherever air has to pass through the floor, with dampers available for airflow control.

  • 1Covering — HPL or PVC (ceramic with holes ≤ 22 mm)
  • 2Perforated top plate — SPCC steel
  • 3Hollow cavity — no cement filling
  • 4Perforated bottom plate
  • 5Adjustable damper (optional) and pedestal / stringer support
Steel ventilation access floor panel with 21 % open area
Perforated steel ventilation panel, top and bottom
Ventilation panel with damper
Steel ventilation panel installed with solid panels

Keunggulan Produk

  1. 1Made of steel plate, high mechanical strength, high loading capacity, good fire resistance.
  2. 2Interchangeable with wood core and calcium sulphate panels.
  3. 3Provides superior cooling for managing heat loads in mission critical facilities.
  4. 4Ventilation rate from 17% to 45% to satisfy different requirements, including clean rooms.

Kapasitas Beban

Steel anti-static ventilation access floor (PRT-TF series)

No.Size (mm)Thickness (mm)Concentrated load (deflection 2 mm) — lbNkgUltimate load (N)Uniform load (N/m²)Rolling load (N)DeflectionPermanent deformationElectrical resistance (Ω)
PRT-TF662600×60030 / 3566229503018850125002255≤2 mm≤0.5 mm10⁶ – 10¹⁰
PRT-TF800600×60035 / 40800355036310650165002950≤2 mm≤0.5 mm10⁶ – 10¹⁰
PRT-TF1000600×600351000445045413350230003560≤2 mm≤0.5 mm10⁶ – 10¹⁰
PRT-TF1250600×600501250556056716680330004450≤2 mm≤0.5 mm10⁶ – 10¹⁰
PRT-TF1500600×600351500666568019995393245560≤2 mm≤0.5 mm10⁶ – 10¹⁰
  • •Perforated top and bottom plates, hollow cavity without cement filling.
  • •Open area 17 % – 45 %; dampers available for stepless adjustment from 0 to the rated open area.
  • •Ceramic tile only with hole diameter ≤ 22 mm and 16 – 64 holes per panel.
  • •Finished floor height 100 – 1000 mm.

Values as published in the PARETE catalogue. Figures are for the panel alone — system performance depends on pedestal spacing and installation.

Aplikasi

IndustryAreas
ManufactureElectronic factory, transformer substation, hydropower plant, oil tank, cement factory, motor industry, etc.
FinancialBank, security, telecom, insurance
CommercialHotel, shopping mall, intelligent office, logistic centre
GovernmentSchool, tax bureau, police station, frontier inspection station, national defence centre, industrial and commercial bureau, customs, national conference centre, etc.
Public facilityHospital, military, highway, airport, TV station, radio and TV centre
Data centre hot and cold aislesClean room air circulationMission-critical rooms with high heat loadUnder-floor air distribution
Perforated panels with 23 % open area in a computer room
Ventilation raised floor in a data centre aisle
Ventilation access floor with ESD PVC facing
Computer room perforated raised floor
Ventilation access floor in a computer room
Perforated panel specification — 27 % open area, concentrated loading 300–567 kg, 5 mm PVC conductive edge
Perforated panel specification — 31 % open area
Perforated panel specification — 38 % open area

Spesifikasi Teknis

Panel seriesVF-1
Panel typePerforated welded steel shell, no cement
Open area21%
Covering optionsHPL, PVC or ceramic tile
AccessoriesAdjustable damper available

Informasi Perdagangan

MerekPARETE
Pesanan Minimum10 m²
Harga SatuanUSD 25 – 80 / m² (decided by technical requirements)
Pengepakan≈ 500 m² per 20 GP container
Gaya PengepakanPARETE logo / Neutral / OEM logo
Waktu Produksi7 – 30 days; 500 m² in 10 days for one 20 GP container
Waktu PengirimanAsia 10 days · Australia 15 days · Middle East / North America 20 days · Africa / Europe / South America / Russia 30 days
Syarat PembayaranT/T, L/C
Kemampuan Pasokan100,000 m² per month